Tagged: SHAULA-791
- This topic has 1 reply, 2 voices, and was last updated 8 years, 2 months ago by admin.
-
AuthorPosts
-
MironGuest
I have installed Astrolabe SMS remote and I want to configure it with my Pyronix alarm system.
The control panel that I have to setup is Shaula 791. I have configured everything through the mobile app but I am not getting calls or sms.
I tried to call and send sms through the sim in the phone and its working. However, it’s not working through the board.
I might be doing something wrong in the Astolabe mbobile app configuration. Please send me the installation guidelines.
adminKeymasterHopefully you have solved the issue by now and sorry for the delay.
Have you wired the system with pyronix 816 as per our basic manual and this blog post?
Please answer the following questions so that we may be better able to know the exact reasons!
- when the Pyronix-816 starts an alarm which status LEDs are ON?. if you can take an image of the Shaula-791 durring an alarm and uplaod it would be helpful.
- Did you program the Pyronix-816 as per instructions in this topic?
STATUS LEDs
This is group of four LEDs that indicate different states and provide important information. Its important to understand these, as these can be very helpful in debugging and troubleshooting. The four LEDs are RED, GREEN, ORANGE and BLUE marked LA, LB ,LC and LD respectively.LA (Red) : Indicates state of intrusion alarm input. If the input at pin-7 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received an Intrusion alarm signal from the alarm system.
LB (Green) : Indicates state of panic alarm input. If the input at pin-8 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received a panic alarm signal from the alarm system.
LC (Orange) : Indicates state of fire alarm input. If the input at pin-9 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received a fire alarm signal from the alarm system.
LD(Blue) : Indicates state of arming. If the input at pin-10 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received a signal from the alarm system indicating that the system is Armed, when this LED is OFF it indicated the system is disarmed. -
AuthorPosts