هذه المشكلة تحتمل عدة أسباب. أحد الأسباب الشائعة هو استخدامك نسخة غير محدّثة من تطبيق قيطس، حيث أن الجهاز المذكور في استفسارك شلياق-172 غير مدعوم في الإصدار القديم من تطبيق قيطس. يرجى التأكد بأنك تستخدم الإصدار 2.4.87 على الأقل. الرجاء متابعة مقطع الفيديو المرفق للتأكد من تحديث اللإصدار
There could be several reasons for this problem. Once common problem could be that your app is not updated to the latest version. SHELIAK-172 is not supported in the older versions of CETUS app. As of now the current version of the CETUS app is 2.4.87. Please check if you have the latest version of CETUS app. Please follow the video below and make sure your app is updated and the version is at-least 2.4.87.
adminKeymasterHopefully you have solved the issue by now and sorry for the delay.
Have you wired the system with pyronix 816 as per our basic manual and this blog post?
Please answer the following questions so that we may be better able to know the exact reasons!
- when the Pyronix-816 starts an alarm which status LEDs are ON?. if you can take an image of the Shaula-791 durring an alarm and uplaod it would be helpful.
- Did you program the Pyronix-816 as per instructions in this topic?
STATUS LEDs
This is group of four LEDs that indicate different states and provide important information. Its important to understand these, as these can be very helpful in debugging and troubleshooting. The four LEDs are RED, GREEN, ORANGE and BLUE marked LA, LB ,LC and LD respectively.LA (Red) : Indicates state of intrusion alarm input. If the input at pin-7 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received an Intrusion alarm signal from the alarm system.
LB (Green) : Indicates state of panic alarm input. If the input at pin-8 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received a panic alarm signal from the alarm system.
LC (Orange) : Indicates state of fire alarm input. If the input at pin-9 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received a fire alarm signal from the alarm system.
LD(Blue) : Indicates state of arming. If the input at pin-10 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V791 received a signal from the alarm system indicating that the system is Armed, when this LED is OFF it indicated the system is disarmed.adminKeymasterHi Ahmed,
The interface instructions for SHAULA-791 are exactly similar to those for SHAULA-V10.
http://www.astrolabetech.com/topic/how-to-connect-shaula-v10-with-pyronex-matrix-816/#post-6996
adminKeymasterWe are happy to know it helped!!
adminKeymasterTo select a country
ADMIN
of the board should go toADMIN TOOLS
from the app,- Tap on select country
- select the country the board is installed in
Here is the excrept from our blog post
To open admin tools page :
Navigate to the remote Page,
Click on extra navigation icon and select the admin tools button.
admin tools labeled
To add admin just click on set admin button. This will bring forward an alert dialog and show the password that will be assigned to the admin which is the password that was entered while creating this account.To set the device id, Enter the desired device id in the text field and press Set ID button. This will set the device ID.
To select the country click on the select country button and select your country from the list of countries.
Hope This will help.
adminKeymasterHi Zaxter!
When I call the panel, my call gets rejected, but the door doesn’t open.
Call rejection Indicates that the System is running well. Please make sure that you have selected your country from admin Tools. If the country is not selected or a wrong country is selected, you would face similar problem.
To make sure that there is no other problem, can you please check if the Gate Opens from the SMS Remote App’s Remote screen?
Regards!
October 12, 2014 at 9:20 am in reply to: How to connect/interface SHAULA-V10 with Pyronix matrix 816 #7018adminKeymasterGreat , We are happy that it helped.
October 11, 2014 at 8:56 pm in reply to: How to connect/interface SHAULA-V10 with Pyronix matrix 816 #6996adminKeymasterTHIS GUIDE WILL WORK FOR SHAULA-791 as well”
INTRODUCTION
SHAULA-V10/SHAULA-791 is a GSM gateway that can provide SMS and Call features for different Alarm systems. The features and functions may vary with firmware versions slightly but in general they are consistent. Below is the summary of features.
- operate gate and door (via two relay on board with C and NC contacts).
- arm & disarm alarm control panel using the app.
- make alert calls in case of intrusion alarm, panic alarm or fire alarm.
- monitor power source notify by SMS if it goes or when it comes back.
- monitor backup battery when main power is absent and notify by SMS if battery is low.
In the figure above SHAULA-V10(SHAULA-791 is basically similar) is shown labelled for important parts , we would explain these parts one by one .
1: STATUS LEDs
This is group of four LEDs that indicate different states and provide important information. Its important to understand these, as these can be very helpful in debugging and troubleshooting. The four LEDs are RED, GREEN, ORANGE and BLUE marked LA, LB ,LC and LD respectively.- LA (Red) : Indicates state of intrusion alarm input. If the input at pin-7 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V10/SHAULA-791 received an Intrusion alarm signal from the alarm system.
- LB (Green) : Indicates state of panic alarm input. If the input at pin-8 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V10/SHAULA-791 received a panic alarm signal from the alarm system.
- LC (Orange) : Indicates state of fire alarm input. If the input at pin-9 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V10/SHAULA-791 received a fire alarm signal from the alarm system.
- LD(Blue) : Indicates state of arming. If the input at pin-10 of IDC connector is Low this LED will be ON, which indicates that SHAULA-V10/SHAULA-791 received a signal from the alarm system indicating that the system is Armed, when this LED is OFF it indicated the system is disarmed.
2: OPERATION LEDs
This is group of three LEDs that indicate different operational states states of SHAULA-V10/SHAULA-791. The three LEDs are RED, BLE and GREEN marked PW, RI, and NW respectively.- PW(Red) : Indicates power status of SHAULA-V10 as soon as power is applied to SHAULA-V10/SHAULA-791 this LED will be ON, If the power is not applied it will be OFF.
- RI(Blue) : Indicates state of incoming SMS or Calls. Its equivalent to the ringer of a phone. It will be ON when there is an incoming call and will blink once for an SMS received.
- NW(Green) : Indicates state of network connection.
- Flash@inverval 800ms: GSM not yet registered to cell phone network.
- Flash@inverval 3000ms: GSM registered to cell phone network.
3: IDC CONNECTOR
In order to work properly,SHAULA-V10/SHAULA-791 requires a few signals to work with , which should be made available on the IDC connector .The IDC connector is a 14 pin (2×7) connector. The pin-outs are as follows. (PIN One is marked as red)
- V+ : Its the first pin of the cable ,denoted by the red wire in the cable, the second wire is also the same V+, It can accept 9V-24VDC input. It is recommended to use 12V or 9V.
- GND: Its the ground wire.
- NC: not connected, Do not connect this wire.
- Intrusion Alarm signal : its the 7th wire, If the wire has a Low signal , SHAULA-V10/SHAULA-791 identifies an intrusion Alarm and will switch on LED LA as explained in the Status LEDs section. If the signal is not Low , LED LA will be OFF indicating no Intrusion alarm.
- Panic Alarm signal : its the 8th wire, If the wire has a Low signal , SHAULA-V10/SHAULA-791 identifies a panic Alarm and will switch on LED LB as explained in the Status LEDs section. If the signal is not Low , LED LB will be OFF indicating no panic alarm.
- Fire Alarm signal : its the 9th wire, If the wire has a Low signal , SHAULA-V10/SHAULA-791 identifies a fire Alarm and will switch on LED LC as explained in the Status LEDs section. If the signal is not Low , LED LC will be OFF indicating no Fire alarm.
- Arming Status signal : its the 10th wire, If the wire has a Low signal , SHAULA-V10 identifies that the Alarm system is Armed and will switch on LED LD as explained in the Status LEDs section. If the signal is not Low , LED LD will be OFF indicating system is disarmed.
- Arm disarm pin: It is an output pin and will provide a pulse of Low signal in order to Arm or disarm the Alarm system.
4: GATE AND DOOR RELAY OUTPUTS
SHAULA-V10/SHAULA-791 can control gate and door using two on board relays. Common and Normal Open signals of both the relays are provided on this connector. Use
N01 and NC1
outputs for gate andN02 and NC2
outputs for gate.
INTERFACING WITH PYRONIX MATRIX-816
As an example we would show settings and connections for Pyronix Matrix-816. Its important that all programming and connections are made correctly , Otherwise SHAULA-V10/SHAULA-791 wont be able to function correctly.
First we would program the programmable outputs of Matrix-816, Using the keypad make the following settings in Pyronix PGM settings on Page 16 function 8.1 of the Pyronix Matrix-816 manual.
PGM3---16 PGM4---11 PGM5---10 PGM6---04
Set output states of PGMs as per page-17 of the programming manual, Set PGM-3,PGM-4,PGM-5, PGM-6 all as off (default is OFF)
Finally we would set one zone to work as key-switch, we would use last zone “zone 8” to work as keys-witch, you may use any other zone as well. To do so make the following programming in Matrix-816
- as on page 7 function 3.2.1 set
program 258
as 11 “Mometary keyswitch” - as on page 4 function 270 set zone 8 as NO “normally open” by default it’s set as NC “normally close”
WIRING
In the image below its shown how to connect IDC pins to Matrix-816 for the programming shown above.
hope this was helpful. Please feel free to reply if you need any more information